The consumer isn't allowed to open up the handles and panel of the system, neither Be aware: gadget disassemble is allowed. To make sure the process overall performance and safety, only Mindray engineers or engineers approved by Mindray can perform maintenance.

The DP-50 Pro is definitely an progressive, large-performance Ultrasound Program engineered to assist you to have the insights you need. The Method’s strong engine and high-velocity processing deliver outstanding image excellent and a whole details administration Option.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Observe: Be sure that you might pull out and thrust into your IO board sockets vertically when pulling out and assembling the IO board assembly about the placement from the take care of. Take out panhead screws with washers M3X6 (four) utilized to safe the IO board, then you could just take out the IO board. Site 116 Clear away panhead screws with washers (two M3X6) which are fastened on the principle unit, just take out the higher baffle and after that pull out two cables connecting the key board to the ability module assembly.

The chapter materials the tactic to verify main purpose and efficiency of product. This is only utilized for reference, not preventive execution. Functionality examining and testing of this element shall be completed by Mindray service engineers along with the consumer alongside one another. Webpage 66: Typical Examination

Don't use any cables besides the cables offered With all the device by Mindray. 3. Use the cable presented with This technique to attach the printer. Other cables may perhaps result in electric shock. Webpage 15: Mechanical Security

Overall performance Exam five.five.one Examination Process Resolution Detection depth Geometric Situation Precision Blackout region take a look at Record the exam illustrations or photos five.five.two Check Content The image applied Here's just for reference, stick to the picture effect in the true Observe: problem. Requirements: Show: established the distinction and brightness within the scientific software worth (or even the default position) Procedure natural environment: darkish area, simulating the clinical software natural environment. Web page seventy six In affliction the transverse resolution tests targets are horizontally shown, document the minimal length of two targets which can be Obviously regarded. Repeat the operation above for the transverse resolution screening targets at other depths. As proven in determine under. Axial resolution ... Web page seventy seven When utilizing the convex probe, retain the transverse resolution screening targets to notice: be displayed close to the midline. When employing a linear probe with steer operate, usually do not activate the steer function when complete the transverse resolution test. Zoom during the area where by the targets located if needed. The diameter in the focus on point at a certain depth is equal on the transverse resolution at the depth. Web page 78 5.

By continuing your stop by on our Internet site, you are consenting to our use of cookies. Nonetheless, you may improve your cookie settings Anytime.  Cookie choice Acknowledge and Progress

Be aware: Prior to uploading the log, make sure the ultrasound process has become linked Dp50rb login to network, otherwise, the procedure may possibly warn “could not hook up with server” The server (smtp.

Immediately after changing the CPU module, crucial file must be produced Yet again in accordance with the new MAC deal with and published into HDD from the device. Or else, the configuration purpose of the merchandise might be lost. Right after eradicating the CPU module, Remove panhead screws with washers (12 M3X6) set on the leading device box, you normally takes from the board. Page 118 Figure 8-29 Disassemble the User interface Assembly (one) Keep the higher fringe of control panel assembly, and open up the control panel. Figure 8-thirty Disassemble the User interface Assembly (two) Immediately after removing 1 countersunk head self-tapping screw PT3X10 set within the control panel and consider out the plug from the keyboard and the primary unit connecting cables, you could remove the user interface assembly.

If you prevent the scanning as well as the impression seize, you should electrical power from the process and disconnect the system from your AC electric power source, then pull out AC power cables. Web page 109: Battery Connecting Board

This guide may well referring to facts secured by copyright or patents and isn't going to convey any license beneath the patent legal rights or copyright of Mindray, or of Some others. Website page 9: Statement

Slice off cable ties connecting the principle device within the Display screen by diagonal reducing pliers, after which you can pull out the corresponding cable plugs.

Written content Method Check the battery periodically : a) Verify if battery could be billed Ordinarily when ability-on: That The existing capability is 100% or ability will increase right after a brief time suggests that the battery is usually charged Usually.